ck pulsar 125 Werkplaats-Handboek : Bladzijde 150

Microfiches
Image preview

Bladzijde 148

Image preview

Bladzijde 149

Image preview

Bladzijde 151

Image preview

Bladzijde 152

1 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170
          15. IGNITION SYSTEM                                                                 Pulsar      CK   125


 CDI UNIT                                              CDI Unit                          CDI Unit Coupler
 REMOVAL
 Remove the seat and fuel tank. (Refer to 4-
 8.)
 Disconnect the CDI unit coupler and remove
 the CDI unit.



 INSPECTION
 Measure the resistance between the CDI unit
 terminals.
 Replace the CDI unit if the readings are not         SW (Black/White)         EXT (Black/Red) E2 (Green)
 within the specifications in the table below.
 The CDI unit is fully transistorized. For
    accurate testing, it is necessary to use a
    specified tester. Use of an improper
    tester or measurements in an improper
    range may give false readings.
    Use a Sanwa Electric Tester SP-10D or
    Kowa Electric Tester TH-5H for testing.


                                                        PC (Blue/      IGN (Black/        E1 (Green/White)
 Testing Range                                          White)         Yellow)
 Use the xK range for the Sanwa Tester.
 Use the x100 range for the Kowa Tester.

                                                                                                    Unit: K
                              (+)Probe    SW        EXT         PC          E2            E1          IGN
                                         (Black/   (Black/    (Blue/                    (Green/       (Black/
                           (-)Probe      White)     Red)      White)      (Green)       White)       Yellow)
                              SW
                             (Black/                                                                   
                             White)
                              EXT                              Needle      Needle
                             (Black/     3-6K                swings then swings then                   
                              Red)                                           
                               PC
                             (Blue/      35-42K    18-22K                 8-10K         8-10K          
                             White
                              E2                                                        There is
                                         15-18K 4.5-5.5K       7-9K                    continuity      
                            (Green)
                              E1                                          There is
                            (Green/      15-18K 4.5-5.5K       7-9K      continuity                    
                            White)
                              IGN
                            (Black/                                                       
                            Yellow)
                           Note: The readings in this table are taken with a Sanwa Tester.



                                                                                                     15-4