1 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 190 195 200 205 210 215 220 225 230 235 240 245 250 255 260 265 270 275 280 285 290 295 300 305 310 315 320 325 330 335 340 345 350 355 360 365 370 375 380 385 390 395 400 405 410 415 420 425 430 435 440 445 450 455 460 462
          6. COOLING SYSTEM                                          UXV 500


 RADIATOR RESERVE TANK

 REMOVAL

 Remove the front fender .

 Remove the two mounting bolts and then
 remove the radiator reserve tank from
 frame.




 Open the reserve tank cap and drain the     Siphon Hose
 coolant from the reserve tank.

 Disconnect the siphon hose.

 INSTALLATION

 Installation is in the reverse order of
 removal.

 Pour the recommended coolant to the upper
 level line with the center stand applied