1 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 190 195 200 205 210 215 220 225 230 235 240 245 250 255 260 265 270 275 280 285 290 295 300 305 310 315 320 325 330 335 340 345 350 355 360 365 370 375 380 385 390 395 400 405 410 415 420 425 430 435 440 445 450 455 460 462
          20. LIGHTS/SWITCHES                                        UXU 500


 FUEL UNIT

 REMOVAL

 Remove the seat
 Remove the fuel unit connectors.
 Remove fuel unit from fuel tank.

 INSPECTION

 Measure the resistance between the
 Yellow/White and Blue/White terminals of
 the fuel unit connector.

 Standard (at 20°C/68°F):
 Float at full position  1100  3% 
 Float at empty position 100  3% 




                                                  Full   Empty
 INSTALLATION

 Fuel unit installation is in the reverse order
 of removal.
    Align the tab on the fuel unit with the
    mark on the fuel tank.




20-9