1 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 190 195 200 205 210 215 220 225 230 235 240 245 250 255 260 265 270 275 280 285 290 295 300 305 310 315 320 325 330 335 340 345 350 355 360 365 370 375 380 385 390 395 400 405 410 415 420 425 430 435 440 445 450 455 460 462
          6. COOLING SYSTEM                                                         UXV 500


 WATER PUMP

 MECHANICAL SEAL INSPECTION

 Inspect the coolant leakage.
 If there is leakage, the mechanical seal is
 defective, and water pump body should be
 replaced.



                                                                   Bypass Hose




 REMOVAL
                                                                     Water Hose
 Drain the coolant (refer to the "COOLANT
 REPLACEMENT" section in this
 chapter).

 Loosen the hose bands and disconnect the
 lower radiator hoses and bypass hose from
 the water pump.




 Remove the four bolts and water pump
 cover and O-ring.
                                               Water Pump Cover/O-ring