uxv 500 Werkplaats-Handboek : Bladzijde 426

Microfiches
Image preview

Bladzijde 424

Image preview

Bladzijde 425

Image preview

Bladzijde 427

Image preview

Bladzijde 428

1 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 190 195 200 205 210 215 220 225 230 235 240 245 250 255 260 265 270 275 280 285 290 295 300 305 310 315 320 325 330 335 340 345 350 355 360 365 370 375 380 385 390 395 400 405 410 415 420 425 430 435 440 445 450 455 460 462
          17. BATTERY/CHARGING SYSTEM                                             UXV 500


 Measure the resistance between each Yellow
 wire terminals.
 Standard: 0.10.3  (20C/68F)

 Check for continuity between each Yellow
 wire terminal of the alternator side connector
 and ground.
 There should be no continuity.

 Replace the alternator stator if resistance is
 out of specification, or if any wire has
 continuity to ground.




                                                  Regulator/Rectifier

 REGULATOR/RECTIFIER

 WIRE HARNESS INSPECTION

 Disconnect the regulator/rectifier connectors.
 Check the connectors for loose contacts of
 corroded terminals.




 Battery line

 Measure the voltage between the Red/White
 wire terminal and ground.
 There should be battery voltage at all times.

 Voltage feedback line

 Measure the voltage between the black wire
 terminal and ground.
 There should be battery voltage with the
 ignition switch "ON", and no voltage with the
 ignition switch "OFF".

                                                                        17-8