1 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 190 195 200 205 210 215 220 225 230 235 240 245 250 255 260 265 270 275 280 285 290 295 300 305 310 315 320 325 330 335 340 345 350 355 360 365 370 375 380 385 390 395 400 405 410 415 420 424
          12. COOLING SYSTEM                                                              DINK50/ 125


                                                 Impeller (Left Hand Threads)
 Install the impeller onto the water pump
 shaft.
 Torque: 1.2 kgf-m (12 N-m, 9 lbf-ft)
 The impeller has left hand threads.




                                                Dowel Pins
 Install the two dowel pins and a new gasket.




                                                               Gasket



                                                        Water Pump Cover
 Install the water pump cover and tighten the
 4 bolts.

 Torque: 1 kgf-m (10 N-m, 7 lbf-ft)




                                                      Bolt