1 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 190 195 200 205 210 215 220 225 230 235 240 245 250 255 260 265 270 275 280 285 290 295 300 305 310 315 320 325 330 335 340 345 350 355 360 365 370 375 380 385 390 395 400 405 410 415 420 424
          13. FUEL SYSTEM/CARBURETOR/
    FUEL PUMP/ FUEL TANK                                       DINK 50/125



 Measure the resistance between the auto
 choke wire terminals.
 Resistance:
      10  below (10 minutes minimum after
                    stopping the engine)
 If the reading is not within the limit, replace
 the auto auto choke with a new one.




 Connect a hose to the fuel enriching circuit
 of the carburetor. Connect the auto choke
 yellow wire to the positive (+) terminal of a
 battery and green/black wire to the negative
 (-) terminal. Wait 5 minutes and blow the
 hose with mouth. If the passage is blocked,
 the auto choke is normal.
 Disconnect the auto choke from the battery.
 Wait 30 minutes and blow the hose with
 mouth. If air can be blown into the hose, the
 auto choke is normal.




 INSTALLATION

 Install the auto choke and set plate.
 Install and tighten the two screws.




                                                   Auto Choke/Set Plate


13-19