1 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 190 195 200 205 210 215 220 225 230 235 240 245 250 255 260 265 270 275 280 285 290 295 300 305 310 315 320 325 330 335 340 345 350 355 360 365 370 375 380 385 390 395 400 405 410 415 420 424
          1. GENERAL INFORMATION                                                           DINK50/125


 POOR CHARGING (BATTERY OVER DISCHARGING OR OVERCHARGING)
 Undercharging

 Inspection/Adjustment                   Symptom                   Probable Cause

 Start engine and test
 limit voltage of battery
 terminals

                                              Voltage does not     Faulty AC generator
                            Normal voltage    increase             Faulty regulator/rectifier
                                                                   Faulty battery

 Measure resistance
 between AC generator
 coil terminals


                               Normal         Resistance too low   Shorted AC generator coil
                                                                   Open circuit between AC
                                                                   generator 3 yellow wires

 Test output voltage of
 regulator/rectifier
 coupler red wire
                                                                   Faulty regulator/rectifier
                                                                   Faulty AC generator
                            Normal voltage         No voltage      Loose regulator/rectifier
                                                                   coupler
                                                                   Limit voltage too high




 Overcharging

 Inspection/Adjustment                   Symptom                   Probable Cause

 Measure battery limit
 voltage with an electric
 tester
                                                                   Faulty battery
                               Normal              Abnormal        Faulty regulator/rectifier
                                                                   Broken or poorly connected
                                                                   regulator/rectifier black wire

 Check resistance
 between regulator/
 rectifier terminals

                              Normal               Abnormal        Limit voltage too high




1-43