1 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 190 195 200 205 210 215 220 225 230 235 240 245 250 255 260 265 270 275 280 285 290 295 300 305 310 315 320 325 330 335 340 345 350 355 360 365 370 375 380 385 390 395 400 405 410 415 420 424
          3. INSPECTION/ADJUSTMENT                          DINK50/125



 VALVE CLEARANCE(DINK 125)

 · Inspect and adjust valve clearance
     while the engine is cold (below 35).


 Remove the two nuts (1) and four bolts (2),
 than remove cylinder head cover.




 Remove the timing hole cap and O-ring (4).
 Remove the crankshaft hole cap and O-ring
 (3).




 Turn the A.C. generator flywheel clockwise
 to the top dead center (TDC) on the
 compression stroke so that the "T" mark (6)
 on the flywheel aligns with the index mark (5)
 on the left crankcase cover.

 The punch mark (7) on the camshaft should
 face upward as shown.

 If the punch mark on the camshaft are facing
 downward, turn the crankshaft clockwise one
 full turn (360°) and the punch mark are facing
 upward.




3-15