1 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 190 195 200 205 210 215 220 225 230 235 240 245 250 255 260 265 270 275 280 285 290 295 300 305 310 315 320 325 330 335 340 345 350 355 360 365 370 375 380 385 390 395 400 405 410 415 420 425 430 435 440 445 450 455 460 462
          18. IGNITION SYSTEM                                                                             UXV 500


RESISTANCE INSPECTION
                                                           Due to the semiconductor in circuit, it
                                                           is necessary to use a specified tester for
Measure the resistance between the terminals.              accurate testing. Use of an improper
                                                           tester in an improper range may give
                                                           false readings.

                                 L/Y
                                                                           G/GR




                                                                           B/W




                                 G/W             B/Y                       G



                                                                  Unit: 
              (+)
   (-)              B/W   G/GR         L/Y      G/W     B/Y         G

         B/W

         G/GR                      6.7 M        6.7 M             6.7 M

         L/Y                                 0.785 K            Continue

         G/W                       0.778 K                       0.785 k

         B/Y

          G                       Continue 0.785 K