1 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 190 195 200 205 210 215 220 225 230 235 240 245 250 255 260 265 270 275 280 285 290 295 300 305 310 315 320 325 330 335 340 345 350 355 360 365 370 375 380 385 390 395 400 405 410 415 420 425 430 435 440 445 450 455 460 462
          19. STARTER SYSTEM                                                                        UXV 500

                                                   Starter Motor Cable
 STARTER MOTOR

 INSPECTION

 Disconnect the starter motor cable from the
 starter MAG.
 Turn the ignition switch to "ON".
 Connect the starter motor cable directly to the
 battery positive terminal.
 If the starter motor does not turn, the starter
 motor is faulty.




                                                                             Rubber Cap
 REMOVAL

 Remove the carburetor


 Turn the ignition switch turned to "OFF"

 Remove the two mounting bolts and starter
 motor.

 Release the rubber cap and remove the
 terminal nut to disconnect the starter motor
 cable from the starter motor.
                                                    Bolts                    Nut


 INSTALLATION
                                                                    O-ring
 Coat a new O-ring with engine oil and install
 it into the starter motor groove.

 Connect the starter motor cable to motor
 terminal with the terminal nut and tighten it.

 Install the starter motor into the crankcase.
 Install the two mounting bolts and tighten them
 securely.




                                                                                          19-4