1 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 190 195 200 205 210 215 220 225 230 235 240 245 250 255 260 265 270 275 280 285 290 295 300 305 310 315 320 325 330 335 340 345 350 355 360 365 370 375 380 385 390 395 400 405 410 415 420 425 430 435 440 445 450 455 460 462
          19. STARTER SYSTEM                                        UXV 500


                                                 Starter MAG
 CONTINUTY INSPECTION

 Disconnect the starter MAG switch connector
 and cables.
 Connect a fully charged 12 V battery positive
 wire to the relay switch Yellow/Red wire
 terminal and negative wire to the
 Yellow/Green wire terminal.

 There should be continuity between the cable
 terminals while the battery is connected, and
 no continuity when the battery is
 disconnected.