dink 50 125 1 Werkplaats-Handboek : Bladzijde 247

Microfiches
Image preview

Bladzijde 245

Image preview

Bladzijde 246

Image preview

Bladzijde 248

Image preview

Bladzijde 249

1 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 190 195 200 205 210 215 220 225 230 235 240 245 250 255 260 265 270 275 280 285 290 295 300 305 310 315 320 325 330 335 340 345 350 355 360 365 370 375 380 385 390 395 400 405 410 415 420 424
          12. COOLING SYSTEM                                                                            DINK50/ 125


 SPECIFICATIONS
  Radiator cap relief pressure                         90 kPa (0.9 kgf/cm2, 12.8 psi)
                            Begins to open             80 - 82°C (176 - 180°F)
  Thermostat temperature Full-open                     90°C (198°F)
                            Valve lift                 3.5 mm (0.14 in) minimum
  Coolant capacity          Radiator and engine        1 liter (1.1 US qt, 0.88 lmp qt)
                               Reserve tank            0.37 liter (0.4 US qt, 0.33 lmp qt)
 Standard coolant concentration                        1:1 mixture with soft water

 COOLANT GRAVITY
         Temp. 
 Coolant             0       5       10      15      20      25      30      35      40      45      50
 concentration
        5%          1.009   1.009   1.008   1.008   1.007   1.006   1.005   1.003   1.001   0.009   0.997
       10%          1.018   1.107   1.017   1.016   1.015   1.014   0.013   1.011   1.009   1.007   1.005
       15%          1.028   1.027   1.026   1.025   1.024   1.022   1.020   1.018   1.016   1.014   1.012
       20%          1.036   1.035   1.034   1.033   1.031   1.029   1.027   1.025   1.023   1.021   1.019
       25%          1.045   1.044   1.043   1.042   1.040   1.038   1.036   1.034   1.031   1.028   1.025
       30%          1.053   1.051   1.051   1.049   1.047   1.045   1.043   1.041   1.038   1.035   1.032
       35%          1.063   1.062   1.060   1.058   1.056   1.054   1.052   1.049   1.046   1.043   1.040
       40%          1.072   1.070   1.068   1.066   1.064   1.062   1.059   1.056   1.053   1.050   1.047
       45%          1.080   1.078   1.076   1.074   1.072   1.069   1.056   1.063   1.062   1.057   1.054
       50%          1.086   1.084   1.082   1.080   1.077   1.074   1.071   1.068   1.065   1.062   1.059
       55%          1.095   1.093   1.091   1.088   1.085   1.082   1.079   1.076   1.073   1.070   1.067
       60%          1.100   1.098   1.095   1.092   1.089   1.086   1.083   1.080   1.077   1.074   1.071

 COOLANT MIXTURE (WITH ANTI-RUST AND ANTI-FREEZING EFFECTS)
   Freezing Point        Mixing Rate      KYMCO SIGMA Coolant Concentrate Distilled Water
      -9                    20%
      -15                   30%                             425cc                            975cc
      -25                   40%
      -37                   50%
      -44.5                 55%

 Cautions for Using Coolant:
 · Use coolant of specified mixing rate. (The mixing rate of 425cc KYMCO SIGMA coolant
   concentrate + 975cc distilled water is 30%.)
 · Do not mix coolant concentrate of different brands.
 · Do not drink the coolant which is poisonous.
 · The freezing point of coolant mixture shall be 5lower than the freezing point of the riding
   area.




12-3