1 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 190 195 200 205 210 215 220 225 230 235 240 245 250 255 260 265 270 275 280 285 290 295 300 305 310 315 320 325 330 335 340 345 350 355 360 365 370 375 380 385 390 395 400 405 410 415 420 424
          12. COOLING SYSTEM                            DINK50/ 125




 RADIATOR
 REMOVAL

 Drain the coolant (see page 12-5).

 Disconnect the siphon hose (1) and air
 bleed hose (2).

 Remove the bolt (3).




 Loosen the hose bands, then disconnect the
 upper radiator hose (4) and lower radiator
 hose (5) from the radiator.


 Disconnect the fan motor switch connectors
 (6).




 Disconnect the air bleed hose (7).
 Disconnect the fan motor connector (8).
 Remove the nut and horn (9)




                                                 12-8