1 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 190 195 200 205 210 215 220 225 230 235 240 245 250 255 260 265 270 275 280 285 290 295 300 305 310 315 320 325 330 335 340 345 350 355 360 365 370 375 380 385 390 395 400 405 410 415 420 424
          16. BATTERY/CHARGING SYSTEM                       DINK 50/125




 ALTERNATOR CHARGING COIL

 INSPECTION

 Remove the luggage box (refer to the
 "FRAME COVERS
 REMOVAL/INSTALLATION" section in
 the chapter 2).

 Disconnect the alternator connector (1).




 Measure the resistance between each Yellow
 wire terminals.

 Standard: 0.40.6  (20C/68F)

 Check for continuity between each Yellow
 wire terminal of the alternator side connector
 and ground.
 There should be continuity.

 Replace the alternator stator if resistance is
 out of specification, or if any wire has
 continuity to ground.

 Refer to chapter 10 for alternator stator
 replacement.




                                                   16-10