ck pulsar 125 Werkplaats-Handboek : Bladzijde 42

Microfiches
Image preview

Bladzijde 40

Image preview

Bladzijde 41

Image preview

Bladzijde 43

Image preview

Bladzijde 44

1 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170
          4. FUEL SYSTEM                                                                     Pulsar      CK   125

 SERVICE INFORMATION.......................4-1      FLOAT LEVEL INSPECTION...............4- 6
 TROUBLESHOOTING .............................4-2   CARBURETOR INSTALLATION ........4- 7
 THROTTLE VALVE DISASSEMBLY ....4-3                 THROTTLE VALVE ASSEMBLY........4- 7
 CARBURETOR REMOVAL.....................4-3         FUEL TANK/FUEL VALVE..................4- 8
 FLOAT/FLOAT VALVE/JETS/                            AIR CLEANER .......................................4-10
 ACCELERATING PUMP..........................4-4



 SERVICE INFORMATION
 GENERAL INSTRUCTIONS

   Gasoline is very dangerous. When working with gasoline, keep sparks and flames away
   from the working area.
   Gasoline is extremely flammable and is explosive under certain conditions. Be sure to
   work in a well-ventilated area.

 · Do not bend or twist control cables. Damaged control cables will not operate smoothly.
 · When disassembling fuel system parts, note the locations of O-rings. Replace them with new
   ones during reassembly.
 · Before float chamber disassembly, loosen the drain screw to drain the residual gasoline into a
   clean container.
 · After the carburetor is removed, plug the intake manifold side with a clean shop towel to prevent
   foreign matters from entering.
 · When cleaning the carburetor air and fuel jets, the O-rings and diaphragm must be removed first
   to avoid damage. Then, clean with compressed air.
 · When the motorcycle is not used for over one month, drain the residual gasoline from the float
   chamber to avoid erratic idling and clogged slow jet due to deteriorated fuel.


 SPECIFICATIONS
          Item                Standard
 Venturi dia.                   22
 Identification number           PD
 Float level                  12.5 mm
 Main jet                       92#
 Control method                Piston
 Idle speed                 1400100rpm
 Throttle grip free play      26mm
 Pilot screw opening             13/4


 SPECIAL TOOL
 Float level gauge

4-1