1 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 190 195 200 205 210 215 220 225 230 235 240 245 250 255 260 265 270 275 280 285 290 295 300 305 310 315 320 325 330 335 340 345 350 355 360 365 370 375 380 385 390 395 400 405 410 415 420 424
          16. BATTERY/CHARGING SYSTEM                                                DINK50/ 125



(DINK 50)
REGULATOR/RECTIFIER INSPECTION
Remove the front cover.

Disconnect the regulator/rectifier wire coupler
and remove the nut to remove the
regulator/rectifier.                                  Nut                      Regulator/Rectifier
Measure the resistances between the terminals.
Replace the regulator/rectifier if the readings are
not within the specifications in the table below.
 · Due to the semiconductor in circuit, it
      is necessary to use a specified tester
      for accurate testing. Use of an
      improper tester in an improper range
      may give false readings.



                                                                              Coupler
        Probe
  Probe(-)      A (R)   B (W)   C (Y)    D (G)
   A (R)                3-4M              
   B (W) 6-8M                             
                                                            A (Red)       C (Yellow)
   C (Y)                                 14-15M
   D (G)                        14-15M




                                                              B (White)      D (Green)